1.
Europace ; 26(5)2024 May 02.
Article En | MEDLINE | ID: mdl-38693772

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Arrhythmias, Cardiac , Cardiomyopathies , Humans , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Female , Male , Cardiomyopathies/therapy , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Middle Aged , Adult , Europe , Surveys and Questionnaires , Stroke Volume , Health Care Surveys , Anti-Arrhythmia Agents/therapeutic use , Practice Patterns, Physicians'/statistics & numerical data , Ventricular Function, Left , Catheter Ablation , Cardiologists
3.
G Ital Cardiol (Rome) ; 25(5): 327-339, 2024 05.
Article It | MEDLINE | ID: mdl-38639123

For many years, cardiac pacing has been based on the stimulation of right ventricular common myocardium to correct diseases of the conduction system. The birth and the development of cardiac resynchronization have led to growing interest in the correction and prevention of pacing-induced dyssynchrony. Many observational studies and some randomized clinical trials have shown that conduction system pacing (CSP) can not only prevent pacing-induced dyssynchrony but can also correct proximal conduction system blocks, with reduction of QRS duration and with equal or greater effectiveness than biventricular pacing. Based on these results, many Italian electrophysiologists have changed the stimulation target from the right ventricular common myocardium to CSP. The two techniques with greater clinical impact are the His bundle stimulation and the left bundle branch pacing. The latter, in particular, because of its easier implantation technique and better electric parameters, is spreading like wildfire and is representing a real revolution in the cardiac pacing field. However, despite the growing amount of data, until now, the European Society of Cardiology guidelines give a very limited role to CSP.


Cardiac Resynchronization Therapy , Heart Failure , Humans , Bundle-Branch Block , Treatment Outcome , Electrocardiography/methods , Heart Conduction System , Cardiac Resynchronization Therapy/methods , Myocardium , Heart Failure/therapy
4.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article En | MEDLINE | ID: mdl-38445836

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Brugada Syndrome , Defibrillators, Implantable , Pacemaker, Artificial , Female , Humans , Male , Middle Aged , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/diagnosis , Brugada Syndrome/complications , Brugada Syndrome/diagnosis , Brugada Syndrome/therapy , Electrocardiography/methods , Electrocardiography, Ambulatory/methods , Adult
5.
JACC Clin Electrophysiol ; 10(4): 670-681, 2024 Apr.
Article En | MEDLINE | ID: mdl-38340116

BACKGROUND: Mitral valve prolapse (MVP) may be associated with ventricular arrhythmias (VA) even in the absence of significant valvular regurgitation. Curling, mitral annulus disjunction (MAD) and myocardial fibrosis (late gadolinium enhancement [LGE]) may account for arrhythmogenesis. OBJECTIVES: This study investigated the determinants of VA in patients with MVP without significant regurgitation. METHODS: This study included 108 patients with MVP (66 female; median age: 48 years) without valve regurgitation. All patients underwent 12-lead electrocardiography, 12-lead 24-hour electrocardiographic Holter monitoring, exercise stress test, and cardiac magnetic resonance. Patients were divided into 2 groups (arrhythmic and no-arrhythmic MVP), according to the presence of VA with a right bundle branch block pattern. RESULTS: The 62 patients (57%) with arrhythmic MVP showed: 1) higher MAD (median length: 6.0 vs 3.2 mm; P = 0.017); 2) higher prevalence of curling (79% vs 52%; P = 0.012); and 3) higher prevalence of left ventricular LGE (79% vs 52%; P = 0.012). Mediation analysis showed that curling had both a direct (P = 0.03) and indirect effect mediated by LGE (P = 0.04) on VA, whereas the association between MAD and VA was completely mediated by LGE. Patients with severe VA showed more pronounced morphofunctional alterations, in terms of MAD (7.0 vs 4.6 mm; P = 0.004) and presence and severity of curling (respectively, 91% vs 64%; P = 0.010; and 4 vs 3 mm; P = 0.004), compared to those without severe VA. CONCLUSIONS: In patients with MVP the occurrence of VA with right bundle branch block morphology is the expression of more severe morphologic, mechanical, and tissue alterations. Curling has both a direct and an indirect effect on VA.


Arrhythmias, Cardiac , Mitral Valve Prolapse , Humans , Female , Middle Aged , Mitral Valve Prolapse/physiopathology , Mitral Valve Prolapse/diagnostic imaging , Mitral Valve Prolapse/complications , Male , Adult , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/epidemiology , Electrocardiography , Magnetic Resonance Imaging , Electrocardiography, Ambulatory , Exercise Test , Aged
6.
Value Health ; 27(4): 527-541, 2024 04.
Article En | MEDLINE | ID: mdl-38296049

OBJECTIVES: Atrial fibrillation (AF) is the most common cardiac arrhythmia, with an increasing incidence and prevalence because of progressively aging populations. Costs related to AF are both direct and indirect. This systematic review aims to identify the main cost drivers of the illness, assess the potential economic impact resulting from changes in care strategies, and propose interventions where they are most needed. METHODS: A systematic literature search of the PubMed and Scopus databases was performed to identify analytical observational studies defining the cost of illness in cases of AF. The search strategy was based on the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) 2020 recommendations. RESULTS: Of the 944 articles retrieved, 24 met the inclusion criteria. These studies were conducted in several countries. All studies calculated the direct medical costs, whereas 8 of 24 studies assessed indirect costs. The median annual direct medical cost per patient, considering all studies, was €9409 (13 333 US dollars in purchasing power parities), with a very large variability due to the heterogeneity of different analyses. Hospitalization costs are generally the main cost drivers. Comorbidities and complications, such as stroke, considerably increase the average annual direct medical cost of AF. CONCLUSIONS: In most of the analyzed studies, inpatient care cost represents the main component of the mean direct medical cost per patient. Stroke and heart failure are responsible for a large share of the total costs; therefore, implementing guidelines to manage comorbidities in AF is a necessary step to improve health and mitigate healthcare costs.


Atrial Fibrillation , Stroke , Humans , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Health Care Costs , Hospitalization , Stroke/epidemiology , Cost of Illness
7.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Article En | MEDLINE | ID: mdl-38272130

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Pacemaker, Artificial , Adult , Female , Humans , Male , Middle Aged , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/complications , Heart-Assist Devices/adverse effects , Pacemaker, Artificial/adverse effects , Treatment Outcome
8.
Heart Rhythm ; 21(5): 555-561, 2024 May.
Article En | MEDLINE | ID: mdl-38242222

BACKGROUND: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG). OBJECTIVE: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG. METHODS: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG. The primary outcome, a composite of appropriate ICD therapies and sudden cardiac death, was assessed along with the clinical predictors of these events. RESULTS: A total of 606 patients (mean age 49.7 ± 14.7 years; 423 [69.8%] men) were followed for a median of 60.3 months (interquartile range 23.0-122.4 months). Nineteen patients (3.1%) experienced life-threatening arrhythmias, with a median annual event rate of 0.5% over 5 years and 0.25% over 10 years. The SCN5A mutation was the only predictor of the primary outcome (hazard ratio 4.54; P = .002), whereas a trend was observed for unexplained syncope (hazard ratio 3.85; P = .05). In patients who were asymptomatic at presentation, the median annual rate of life-threatening arrhythmias is 0.24% over 5 years and increases to 1.2% if they have inducible ventricular fibrillation during programmed ventricular stimulation. CONCLUSION: In patients with drug-induced type 1 Brugada ECG, the annual risk of life-threatening arrhythmias is low, with the SCN5A mutation as the only independent predictor. Unexplained syncope correlated with worse clinical outcomes. Ventricular fibrillation inducibility at programmed ventricular stimulation significantly increases the median annual rate of life-threatening arrhythmias from 0.24% to 1.2% over 5 years.


Brugada Syndrome , Electrocardiography , Registries , Humans , Male , Brugada Syndrome/physiopathology , Brugada Syndrome/diagnosis , Brugada Syndrome/epidemiology , Female , Middle Aged , Retrospective Studies , Prognosis , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Italy/epidemiology , Follow-Up Studies , Defibrillators, Implantable , Switzerland/epidemiology , Time Factors , Survival Rate/trends , Adult
10.
J Interv Card Electrophysiol ; 67(1): 175-182, 2024 Jan.
Article En | MEDLINE | ID: mdl-37365481

BACKGROUND: The Medtronic SelectSecure Model 3830 lumenless lead (Medtronic, Inc., Minneapolis, MN) is commonly used for conduction system pacing (CSP). However, with this increased use, the potential need for transvenous lead extraction (TLE) also will increase. While extraction of endocardial 3830 leads is rather well described especially in pediatric and adult congenital heart disease population, there is very limited data on extraction of CSP leads. In the present study, we reported our preliminary experience on TLE of CSP leads and provided technical considerations. METHODS: The study population comprised 6 consecutive patients (67% male; mean age 70 ± 22 years) with CSP leads (3830 leads), including left bundle branch pacing (LBBP) lead (n = 3) and His pacing lead (n = 3) undergoing TLE. Overall target leads were 17. The mean implant duration time of CSP leads was 97 ± 90 months [range 8-193). RESULTS: Manual traction was successful in 2 cases and mechanical extraction tools were required in the remaining cases. Sixteen leads (94%) were completely extracted, whereas incomplete removal was observed in one lead (6%) among 1 patient. Of note, in the only lead incompletely removed, we observed retention of < 1-cm remnant of lead material consisting of the screw of 3830 LBBP lead into the interventricular septum. No failure of lead extraction was reported and no major complications occurred. CONCLUSIONS: Our findings demonstrated that at an experienced center the success of TLE of chronically implanted CSP leads is high in the absence of major complications also when mechanical extraction tools are needed.


Heart Defects, Congenital , Pacemaker, Artificial , Humans , Male , Adult , Child , Middle Aged , Aged , Aged, 80 and over , Female , Retrospective Studies , Device Removal , Heart Defects, Congenital/surgery , Cardiac Pacing, Artificial , Cardiac Conduction System Disease
12.
Int J Cardiol ; 397: 131614, 2024 Feb 15.
Article En | MEDLINE | ID: mdl-38016624

BACKGROUND: The Petersen' index reflects an excess of myocardial trabeculation which is not a specific morpho-functional feature of left ventricular non-compaction (LVNC) cardiomyopathy, but a "phenotypic trait" even observed in association with other myocardial diseases and over-loading conditions. The present study was designed to evaluate the relation between a critical thinning of compact layer and the development of systolic dysfunction and LVNC cardiomyopathy. METHODS: We compared CMR morpho-functional features and measurements of LV wall thickness using a 17 segment model of a cohort of patients fulfilling the Petersen criterion for LVNC with LV systolic dysfunction versus those of a cohort of age- and sex-matched controls with LVNC and preserved LV systolic function. All the study patients had an "isolated" LVNC defined as positive Petersen criterion in the absence of other diseases such as hypertrophic and dilated cardiomyopathy, valvular heart disease, or congenital heart disease and over-loading conditions. RESULTS: he study population included 33 patients with "isolated" LVNC: 11 consecutive index patients with a reduced LV ejection fraction (LVNCrEF) and 22 controls with a preserved LVEF (LVNCpEF). The compact myocardial layer was thinner in patients with LVNCrEF than in those with LVNCpEF patients, both in mid-ventricular and apical LV segments. On linear regression analysis, there was a linear correlation between median thickness of mid-ventricular free wall segments and left ventricular ejection fraction (r = 0.51, p = 0.005). On the ROC curves analysis, ≥2 segments with a compact myocardial layer <5 mm in the free wall mid-ventricular segments showed the best accuracy for reduced LVEF (100% sensitivity and 60% specificity; AUC 0.81, p < 0.01). The negative predictive value for LV systolic dysfunction of <2 free wall mid ventricular segments <5 mm was 100%. On quantitative analysis, the mass of papillary muscles was lower in patients with LVNCrEF [1.2 (0.8-1.4) versus 1.6 (1.1-1.8) g/mq; p = 0.08]. CONCLUSIONS: A thinned compact layer of mid-ventricular segments of the LV free wall was associated with a reduced systolic function and "isolated" LVNC cardiomyopathy.


Cardiomyopathies , Isolated Noncompaction of the Ventricular Myocardium , Ventricular Dysfunction, Left , Male , Humans , Stroke Volume , Ventricular Function, Left , Isolated Noncompaction of the Ventricular Myocardium/diagnostic imaging , Cardiomyopathies/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Predictive Value of Tests , Magnetic Resonance Spectroscopy , Magnetic Resonance Imaging, Cine
13.
Europace ; 26(1)2023 12 28.
Article En | MEDLINE | ID: mdl-38091971

Limited data are available regarding venous thromboembolism (VTE), specifically deep vein thrombosis (DVT) and pulmonary embolism (PE), following right-sided ablations and electrophysiological (EP) studies. Compared to left-sided procedures, no guidelines on antithrombotic management strategies for the prevention of DVT and PE are available. The main purpose of the present European Heart Rhythm Association (EHRA) survey is to report the current management of right-sided EP procedures, focusing on anticoagulation and prevention of VTE. An online survey was conducted using the EHRA infrastructure. A total of 244 participants answered a 19-items questionnaire on the periprocedural management of EP studies and right-sided catheter ablations. The right femoral vein is the most common access for EP studies and right-sided procedures. An ultrasound-guided approach is employed by more than 2/3 of respondents. Intravenous heparin is not commonly given by the majority of participants. About 1/3 of participants (34%) routinely prescribe VTE prophylaxis during (mostly aspirin and low molecular weight heparin) and 1/4 of respondents (25%) commonly prescribe VTE prophylaxis after discharge (mostly aspirin). Of note, respectively 13% and 9% of participants observed at least one DVT and one PE related to right-sided ablation or EP study within the last year in their center. The present survey shows that only a minority of operators routinely gives intraprocedural intravenous heparin and prescribes VTE prophylaxis after right-sided EP procedures. Compared to left-sided procedures like atrial fibrillation (AF) ablation, there are no consistent systematic antithrombotic management strategies.


Pulmonary Embolism , Venous Thromboembolism , Humans , Venous Thromboembolism/epidemiology , Venous Thromboembolism/prevention & control , Anticoagulants/therapeutic use , Fibrinolytic Agents/therapeutic use , Heparin , Pulmonary Embolism/prevention & control , Pulmonary Embolism/drug therapy , Aspirin , Surveys and Questionnaires
14.
J Cardiovasc Dev Dis ; 10(12)2023 Nov 25.
Article En | MEDLINE | ID: mdl-38132643

Unstable and symptomatic complete atrioventricular block represents a potentially fatal condition that requires prompt therapy while waiting for definitive pacemaker implantation. Although transcutaneous pacing is included in acute management, it could be a difficult approach due to its painfulness and the occasional failure of mechanical capture. Drug therapy is a feasible choice, and current guidelines encompass the use of atropine, dopamine, or epinephrine. Isoprenaline has never been investigated in this setting, and no specific indication of its use has been provided despite its potentially more favorable pharmacological profile. The study population included a consecutive series of patients who presented to the emergency department because of unstable third-degree atrioventricular block and were treated with either isoprenaline or dopamine infusion while waiting for definitive pacemaker implantation. Asymptomatic patients or those with reversible causes of complete atrioventricular block were excluded. The clinical response to the drug was deemed poor if, despite achieving a full drug dose, patients remained symptomatic and/or with hemodynamic instability, ventricular rate and rhythm did not improve or worsened, including if ventricular arrhythmias or asystolic pauses and/or irrepressible nausea/vomiting occurred. Isoprenaline infusion has proved to be safe and tolerated with no arrhythmia induction or hypotensive issues. Isoprenaline has also proven to be more satisfactory in achieving an effective clinical response in 84% of patients rather than dopamine (31%, p < 0.001), reducing the need for temporary artificial pacing. Our data point out the efficacy and safety of isoprenaline infusion and its greater tolerability over dopamine in the acute management of unstable third-degree AV block while waiting for definitive pacemaker implantation.

15.
Article En | MEDLINE | ID: mdl-38114717

A 74-year-old man who recently undergone a definitive pacemaker implantation with an apical septal active lead fixation presented to the emergency department because of a new-onset acute chest pain that began soon after cough episodes. Pacemaker interrogation reported an increased bipolar pacing threshold (3.25 V at 1 ms). Contrast-enhanced chest CT scan and percutaneous angiography revealed the sequential perforation of the right ventricular apex and the left internal mammary artery by the ventricular pacemaker lead. Successful percutaneous embolization of the LIMA, blood transfusion and thoracentesis were then performed, and the patient subsequently underwent a percutaneous ventricular lead extraction followed by re-implantation, with an uneventful follow-up after 2 years. This unique case report highlights a potential rare complication of the active fixation of the ventricular lead at the apical interventricular septum and should lead the clinicians to keep in mind right ventricular perforation, even without cardiac tamponade, in patients presenting for cardio-pulmonary symptoms soon after pacemaker implantation.

17.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37724686

AIMS: The implantable cardioverter-defibrillator (ICD) is a life-saving therapy in patients with hypertrophic cardiomyopathy (HCM) at risk of sudden cardiac death. Implantable cardioverter-defibrillator complications are of concern. The subcutaneous ICD (S-ICD) does not use transvenous leads and is expected to reduce complications. However, it does not provide bradycardia and anti-tachycardia pacing (ATP). The aim of this study was to compare appropriate and inappropriate ICD interventions, complications, disease-related adverse events and mortality between HCM patients implanted with a S- or transvenous (TV)-ICD. METHODS AND RESULTS: Consecutive HCM patients implanted with a S- (n = 216) or TV-ICD (n = 211) were enrolled. Propensity-adjusted cumulative Kaplan-Meier curves and multivariate Cox proportional hazard ratios were used to compare 5-year event-free survival and the risk of events. The S-ICD patients had lower 5-year risk of appropriate (HR: 0.32; 95%CI: 0.15-0.65; P = 0.002) and inappropriate (HR: 0.44; 95%CI: 0.20-0.95; P = 0.038) ICD interventions, driven by a high incidence of ATP therapy in the TV-ICD group. The S- and TV-ICD patients experienced similar 5-year rate of device-related complications, albeit the risk of major lead-related complications was lower in S-ICD patients (HR: 0.17; 95%CI: 0.038-0.79; P = 0.023). The TV- and S-ICD patients displayed similar risk of disease-related complications (HR: 0.64; 95%CI: 0.27-1.52; P = 0.309) and mortality (HR: 0.74; 95%CI: 0.29-1.87; P = 0.521). CONCLUSION: Hypertrophic cardiomyopathy patients implanted with a S-ICD had lower 5-year risk of appropriate and inappropriate ICD therapies as well as of major lead-related complications as compared to those implanted with a TV-ICD. Long-term comparative follow-up studies will clarify whether the lower incidence of major lead-related complications will translate into a morbidity or survival benefit.


Cardiomyopathy, Hypertrophic , Defibrillators, Implantable , Humans , Cardiomyopathy, Hypertrophic/complications , Cardiomyopathy, Hypertrophic/therapy , Bradycardia , Disease Progression , Adenosine Triphosphate
18.
J Cardiovasc Dev Dis ; 10(8)2023 Jul 27.
Article En | MEDLINE | ID: mdl-37623332

Acute myocardial edema (AME) is increased water content in the myocardium and represents the first and transient pathophysiological response to an acute myocardial injury. In-vivo and non-invasive evaluation is feasible with cardiac magnetic resonance (CMR), which is a powerful imaging technique capable of tissue characterization. In the clinical setting, early demonstration of AME has a recognized diagnostic value for acute coronary syndromes and acute myocarditis, although its prognostic value is not well established. This article provides a comprehensive narrative review on the clinical meaning of AME in heart diseases. In particular, the available evidence of a possible favourable prognostic value in several clinical scenarios is addressed.

20.
Europace ; 25(9)2023 08 02.
Article En | MEDLINE | ID: mdl-37536671

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Cardiomyopathies , Channelopathies , Defibrillators, Implantable , Humans , Defibrillators, Implantable/adverse effects , Channelopathies/complications , Channelopathies/therapy , Treatment Outcome , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Cardiomyopathies/complications , Cardiomyopathies/therapy , Registries
...